RF-222 10A Ventilation Regulator (Fan+Cooling+Heating+2nd Fan+0-10V)
RF-222 10A ventilation regulator (Fan+Cooling+Heating+2nd fan+0-10V).
This is the ideal equipment for environmental control in a weaning or farrowing room.
Easy to use, robust, reliable and fully functional.
Quantity | > 3 |
Precio unitario | €276.88 |
FEATURES:
Watertight PVC box with digital colour display
Maximum and minimum temperature recording and display on screen.
Includes 1 temperature probe.
Data backup in case of power failure
1 adjustable 0-10V proportional output for connection to auxiliary equipment.
3 power-free auxiliary relays for connection of heating, cooling and auxiliary fan systems.
Probe error detection.
Ventilation regulation based on programmable set temperature, passband and maximum and minimum ventilation limits.
Heating/cooling/2nd fan regulation based on programmable set temperatures and passbands.
TECHNICAL SPECIFICATIONS:
Supply voltage: 230 Vac / 50 Hz
Maximum ventilation load: 10 A
Maximum relay load: 2 A / 240V
Temperature measurement range 4.0 / 45ºC
Measurement accuracy: 0.1 ºC
Proportional outputs: 0- 10 Vdc
Overload protection (motor): 10A fuse
Overload protection (operation): 0.125A fuse
Dielectric strength: 2500V
Dimensions: 220X168X85 mm
Do you need more information about this product? We help you. Call to 976 67 78 65 or contact us.